Operation skills of 350S125 double suction centrifugal pump
350S125 double suction centrifugal pump has good anti cavitation performance, stable operation and long service life. In selecting, we should refer to the main technical data of its performance, including flow rate, lift, speed, efficiency and specific speed, etc.. During the run, people need to know some skills.
1, filler wear inch, can be properly pressed packing gland. If excessive wear, should be replaced.
2, regular inspection Zhen couplings, pay attention to the motor bearing temperature rise.
3, in the process of operation, such as sound or other edged unusual sound, should immediately stop. Investigate the cause.
4, double suction pump opening, the maximum temperature shall not exceed 75 degrees C.
5, the number of calcium base grease used in the lubrication bearing should be 1/3 of the bearing space.
6, shall not arbitrarily increase the speed of the pump. But it can reduce the speed.
Reasonable selection of 350S125 double suction centrifugal pump, taking into account the relevant technical and economic indicators, must meet the use of flow and lift requirements, so that the power is not easy to damage the parts.